- SKU: compresor-de-aire-grado-medico-5-hp-quadruplex
- BARCODE: compresor-de-aire-grado-medico-5-hp-quadruplex
- VENDOR: Prosalud.me
Powerex 5 HP QUADRUPLEX 240 Gallon Medical Grade Air Compressor Cat. PWX-MPQ0508
Taxes included.
Shipping calculated at checkout.
Couldn't load pickup availability
5 HP QUADRUPLEX 240 Gallon Medical Grade Air Compressor Cat. PWX-MPQ0508 Powerex
Description:
Medical Grade oil-free reciprocating air compressor, air-cooled, 5 HP Quadruplex configuration with 240-gallon vertical tank and refrigerated dryers Mod. MPQ0508
- MODEL: MPQ05083K4
- POWER: 20 HP Total (5 HP x 4)
- AIR VOLUME: 55.8 SCFM @ 50 PSIG
- TANK: 240 GALLONS VERTICAL
- VOLTAGE: 230 VOLTS / 60 HZ / 3 PHASES
- REFRIGERATIVE DRYERS
Features:
- POWEREX BRAND 100% ORIGINAL, MANUFACTURED AND ASSEMBLED IN U.S.A.
- The medical reciprocating air system is a tank-mounted design consisting of duplex oil-free piston compressors, dual air dryers with purge control, dual filtration system, dew point, and CO monitors.
- Wired control panel, all mounted on a corrosion-resistant air receiver.
- The tank-mounted package is fully integrated into the design and complies with current NFPA 99 standards.
- The tank-mounted package is provided with single-point connections for electrical, air discharge, and condensate drains. All systems are operationally tested before shipment.
Oil-free reciprocating compressor pump:
- The oil-free reciprocating air compressor pump has a completely oil-free design and does not require oil for its operation.
- Composite piston technology, dual cooling fans, and sealed bearings provide high-quality, low-maintenance, oil-free air.
- Pistons are made of heat-repelling composite resin with piston rings constructed of PTFE material.
- Piston rings have a minimum service life of 10,000 operating hours.
- Each compressor will be equipped with the following components:
- Isolation valve, check valve, and safety valve.
- ODP electric motor, drive pulley, belts, and belt guard.
- Air-cooled aftercooler with moisture separator.
- T.M.P.D. (Thermal malfunction protection device)
- Spring isolators.
Receiver tank:
The ASME National Board registered a working pressure of 200 psig. This horizontal air receiver is equipped with:
- Pressure gauge
- Safety valve
- Visual indicator
- Manual and automatic tank drain.
- 3-valve bypass plumbing
- External paint and internal lining to resist corrosion.
Control panel NFPA CONTROL PANEL
- NEMA 12, UL508A listed and labeled with two control transformers with fused primary and secondary circuits.
- The panel has automatic alternation and "in use" reserve alarm with visual and audible indicators.
- All alarms have dry contacts on a labeled terminal strip for remote alarms.
- The panel will provide power for the complete system, including all desiccant dryers, drains, monitors, and alarms, with a single-point electrical connection. Each compressor will be equipped with the following:
- Disconnect.
- Magnetic starter.
- Illuminated HOA switch.
- High-temperature shutdown with visual and audible alarms.
- Hour meter.
Air-cooled aftercoolers:
- Aftercoolers mounted on the belt guard are provided for each compressor and are sized for a 15 ºF approach temperature.
- Units are constructed with copper tubes with metallic headers.
Air purification system:
- Dual refrigerated air dryers.
- Dual pre-filters.
- Dual pressure reducing valves with gauges and safety relief valves.
- Automatic dew point dependent switching to reduce purge frequency.
Monitoring equipment:
- CO monitor with audible/visual alarms and dry contacts for remote alarm signal.
- Dew point monitor with audible/visual alarms and dry contacts for remote alarm signal.
System connections:
- The system is supplied with a remote intake connection and flexible connectors for intake and discharge.
- All piping complies with current NFPA 99 requirements.
- Includes isolation pad.
NOTE: Does not include startup and commissioning
- Free shipping on orders over $50
- Standard delivery within 2–5 business days
- Easy 30-day returns
- Return items in original condition for a full refund